ELECTRICAL INSTALLATION
5
35
8021804/2017-11-27|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L I N S T R U C T I O N S | Telematic Data Collector
5.1.4
Connecting the TDC device to SICK sensors
SICK sensors are usually connected to the TDC device via two digital inputs. Depending on
how many sensors are connected to the TDC device, use the two wires of the connecting
cable for the voltage supply (TDC devices in the B series only) or a suitable INPUT cable
for the connection.
The wires are to be connected by the customer to the connecting cable of the relevant
sensor via a compatible Micro-Fit adapter (4- or 6-pin).
Voltage can be supplied to the sensor via the voltage supply to the CAN bus or the RS485
bus.
The TDC devices also feature interfaces that can be used to connect sensors from third-
party providers.
For additional information on the connection, please see the operating instructions for the
relevant TDC device or sensor.
Connecting the TDC-B100/TDC-B200 to a sensor
Fig. 24: Connecting the TDC-B100 /TDC-B200 to SICK sensors
1. Plug the Micro-Fit male connector on the connecting cable for the TDC device into the
Input
female connector.
2. For each sensor, connect two wires to the connecting cable of the corresponding
sensor via an adapter.
Inputs
Pin
Wire color
Connection
1
Blue
IN C
2
Pink
IN D
3
Gray
IN D
4
Violet
IN F
5
White
IN G
6
Brown
IN H
Tab. 14: Connecting the TDC-B100 /TDC-B200 to SICK sensors