Modes of operation
Intelli-FLEX II product guide • • • 6 - 9
Cut Profile LED
Indicates that the displayed parameter is the Cut Profile for the indicated zone.
The display shows the percentage (i.e. 01 = 10%) that the cut window is
extended for each cut event that is recorded. For example, a displayed value of 01
would extend the cut window time of 30 seconds by three additional seconds
each time a cut event is recorded. This allows shorter cut windows to be selected.
The factory preset value is 02.
Peak Trigger LED
Indicates that the display shows the Peak Trigger parameter. This parameter
determines the value of the input signal used by the processor to distinguish
intrusion events from environmental activity. The value may be changed for
unusual fence structures or mounting configurations. Factory setting is 03 (30%).
Ambient Compensation LED
Indicates that the display value shows the amount of ambient compensation that
is in effect. The user may specify the amount of ambient compensation which will
be added to the Cut and Climb base Thresholds. An entry of ten (10) means
(100%) ambient compensation will be in effect. The factory setting is 10.
The system constantly evaluates the signal from the sensor cable. This provides
considerable information concerning environmental activities which tend to be
gradual in nature and of long duration. Wind and Rain for instance, are more
gradual and longer lasting than an intruder cutting or climbing a fence. This long
term data is evaluated by the micro-processor. This ambient signal can be
effectively ignored and only the signals which are outside this ambient, consistent
region, will be evaluated for Cut and Climb significance.
Common Mode LED
Indicates if Common Mode is enabled (01) or disabled (00). When enabled,
Common Mode evaluates the ambient activity in both zones to determine if
Ambient Compensation should be applied to the zones. When Common Mode is
enabled (01) the ambient readings in both zones must be similar or Ambient
Compensation will not take place, When Common Mode is disabled (00) Ambient
Compensation will always take place. The factory setting is 00.