Installation of cable at gates
5 - 22 • • • Intelli-FLEX II product guide
Installation instructions
1. Place the male cap stay wire over the open end of the non-sensitive feed cable
on the male connector, put the cap in place, (on the connector) during
installation to ensure proper placement.
2. Wrap a hose clamp (customer supplied) around the fixed post on the opening
side of the fence on which the gate disconnect will be mounted.
3. Before tightening the clamp, position the L-shaped bracket under the clamp
against the post.
4. Tighten the hose clamp until the entire assembly is firmly attached to the
post.
5. Dress the non-sensitive feed cables to the splice kits with cable ties.
Be sure to form a drip loop on the top wire, see Figure
5-22, Sliding gate disconnect assembly, on page 5-21.
6. Follow the directions for a standard splice. See “Splice kit” on page 34.
When caps are not in use, they fit into one another for
storage, and to protect from excess movement or
moisture. The connectors should be capped when the
gate is to remain open for extended periods.
7. Attach the rubber boot cover over the disconnect assembly.