Installing the Intelli-FLEX II processor
5 - 38 • • • Intelli-FLEX II product guide
Installation guidelines
Consult the local electrical code for power and
grounding requirements.
When installing an Intelli-FLEX II processor, keep the following points in mind:
•
to help prevent tampering Senstar, recommends that you install the processor
on the secure side of the perimeter at a location other than on the fence
where the sensor cable is installed
•
if razor ribbon is installed along the bottom of the fence, mount the processor
away from any razor ribbon
•
install the processor near eye-level (above the high snow level)
•
mount the enclosure so that the cable entry holes are on the bottom toward
the ground (2 holes, one for feed cables and alarm communication wiring,
one for power and ground)
•
keep the power and ground cables away from the feed cables
•
install all cables to the processor inside conduit
•
the F-connectors will not fit through the conduit fittings
•
locate the processor close to the protected fence so that one person can easily
perform calibration or maintenance tasks
Installation procedure
1. Using the supplied hardware, attach the four mounting feet to the enclosure.
2. Position the enclosure in the intended mounting location and mark the
locations of the holes.
3. Drill the mounting holes.
4. Using appropriate hardware for the mounting surface (customer supplied)
mount the enclosure.