Gate bypass module
5 - 28 • • • Intelli-FLEX II product guide
End of zone
Materials required
1 - Model 2490-1 Gate bypass module
1 - cable termination kit
Figure 5-28 End of zone
Pin #
cable description
Pin #
cable description
1
from annunciator - tamper status - N/O
(closed when faceplate assembly is in place)
7
shield/ground
2
from annunciator - tamper status - common
8
not used
3
center conductor from prior section of the
zone
9
internal 1M
Ω
resistor
4
tie point for coax shield
10
from annunciator - bypass status - common
5
center conductor of cable to the gate or
ending sensor section
11
from annunciator - bypass status - N/C
6
not used
A
1
2
3
4
5
6
7
8
9 10 11
J1
B
A
B
Cable connections
A from prior section of zone
B sensor cable on gate section
gate bypass module
splice kit (1)
from
annunciator
from
annunciator
jumper