Perimeter layout guidelines
Intelli-FLEX II product guide • • • 4 - 15
The enclosure includes four mounting feet and the hardware for attaching the
mounting feet to the enclosure. Mounting hardware for the enclosure is customer
supplied.
AC or DC power wiring
The DC power/float charger and battery or the 24 VDC power supply require
primary power. A separate enclosure may be required at the processor locations
for power distribution and circuit breaker installations, if the 115 VAC power is
routed outdoors to a location near the processors. Normally, if primary power is
not conveniently located, 24 VDC is run to the processors.
In locations where the AC power supply may not be stable or reliable, an
uninterruptable power system (UPS) should be considered for primary power, in
conjunction with the 24 VDC power supply. See also
Alarm monitoring
The processors have both intrusion alarm and line supervision alarm relays for
each zone. These relays are to be connected to monitoring equipment.
Grounding considerations
The Intelli-FLEX II sensor must have a single ground reference. This earth ground
must be located at each processor. A stable earth ground is required at the
processor mounting location. The entire system is referenced to this ground.
Refer to the local electrical code for grounding requirements.
Cable connectors
The splice kit is used to join two cables together within a zone, either sensor
cable to sensor cable or sensor cable to non-sensitive feed cable. It is mounted
horizontally to a fence post or fence fabric using two tie wraps.
The termination kit is installed at the end of a zone to allow supervision of the
sensor cable. It is mounted horizontally to a fence post or fence fabric using two
tie wraps.