![SENSTAR Intelli-FLEX II Product Manual Download Page 28](http://html.mh-extra.com/html/senstar/intelli-flex-ii/intelli-flex-ii_product-manual_1244251028.webp)
Perimeter layout guidelines
4 - 10 • • • Intelli-FLEX II product guide
Palisade fences
Figure 4-6 Cable installation on Palisade fence
On palisade fences the sensor cable should be deployed in a square wave pattern
with the top and bottom sections attached to the upper and middle support. On
palisade fences greater than 2 m (6 ft., 6 in.) in height, an alternative method of
cable deployment is recommended. Usually such fences have three horizontal
supports.
Outrigger arrays
Figure 4-7 Cable installation on barbed wire outrigger array
In a barbed wire outrigger array, if the wires in the array are less than 10 cm (4 in.)
apart, the sensor cable will be laid out on the array in a saw-tooth pattern.