Standard components
Intelli-FLEX II product guide • • • 3 - 3
A plug-in connector allows you to connect the configuration module to the
processor.
Intelli-FLEX II processors containing relay outputs can be used with existing
E-Flex sensor cable installations. They can replace existing EIIA, EIIAHR, EIIB,
EIIBHR and E3i processors.
Sensor cables
Intelli-FLEX sensor cables are sensitive to physical disturbance. Because they are
mounted directly on existing fences, anything that causes the fence fabric to
vibrate, such as shaking or hitting the fence, will be transferred to the sensor
cable.
These disturbances generate electronic signals that are representative of the fence
activity. The signals are passed from the sensor cables to the processor where they
are analyzed.
Non-sensitive feed cable
The non-sensitive coaxial feed cable does not detect vibrations. It is used
primarily in two instances. In both cases, the non-sensitive feed cable allows the
signals that are generated through the sensor cable to be routed to the processor.
The sensor cable cannot be connected directly to the processor, therefore, a
section of non-sensitive feed cable, complete with an F-connector, is spliced to
the end of the sensor cable. The feed cable is then connected to the processor at
the F-connector.
The non-sensitive feed cable is also used to bypass gates or buildings. This is
accomplished by splicing a section of the feed cable to the sensor cable zone at
the location of the gate or building.
The input power of the Intelli-FLEX II processor may be different
from the existing one. Be sure to use the new power transformer. If
you are using distributed power, consult Senstar to determine the
compatibility with existing installations.