Cable devices
5 - 36 • • • Intelli-FLEX II product guide
Termination kit
The termination kit is installed at the end of a zone to allow supervision of the
sensor cable. It is mounted horizontally and attached to a fence post or fence
fabric using two tie wraps.
Materials
•
1 gel shell
•
1 terminal block
•
1 one Megohm resistor
Installation instructions
1. Separate the shield and center conductor, twist the shield into a 'solid strand'.
2. Connect the sensor cable center conductor to one post of the terminal block.
Make sure that the screw terminals are open enough to accept wires.
3. Connect the shield to the adjacent post.
4. Connect the resistor (1 Meg) across the opposite terminals.
5. Place the terminal block into the gel cavity of the shell.
6. Snap the two halves of the shell together.
7. Secure the completed assembly to the fence fabric horizontally at the top of
the drip loop, (see “Drip loop” on page 4), using two UV-resistant tie wraps.
Figure 5-35 Termination kit
1M resistor
upper half shell
lower half shell
enclosure snaps closed
terminal block
Do not short the shield to the center conductors.
Caution