Configuration settings
7 - 8 • • • Intelli-FLEX II product guide
Cut and climb detection testing in Zone 2
To perform the cut and climb detection testing for zone 2, set up the
configuration module so that the
Monitor
and
Zone 2
LEDs are lit and the desired
threat assessment LED (
Cut
or
Climb
) is lit, then proceed with the instructions
described for Zone 1.
Configuration settings
The following are detailed step-by-step examples of how to view and change the
Intelli-FLEX II configuration settings. A procedure similar to the examples below
is used to sequence, view or change the other configuration settings.
Cut Count - Zone 1
To view or change the number of Cuts required to initiate an alarm in Zone 1
proceed as follows:
1. Connect the Configuration module to the processor.
2. Enter configuration mode by pressing
Mode Select
.
The
Configure
,
Zone 1
,
Cut
and
Time Window
LEDs are lit. The display shows
the number of seconds that the time window is currently set to.
3. Press
Display Select
twice to sequence the display and LEDs to show
Zone 1
,
Cut
and
Cut Count
.
The display now shows the number or cuts that must be detected within the
cut window to initiate an alarm.
If your intent was to view the parameter you are finished. To change the
parameter, continue.
4. Use
Increase
or
Decrease
as necessary to change the value for the
Zone 1,
Cut,
Cut Count
.
•
Pressing
Increase
will increase the parameter value by one unit each time
the key is pressed.
•
Pressing
Decrease
will decrease the parameter value by one unit each
time the key is pressed.
5. When the desired value is displayed, press
Load
.
Load must be pressed immediately after Increase or
Decrease for the new value to the saved, otherwise the
original value will be retained.