www.weg.net
Manual of Electric Motors
85
E
N
G
LI
S
H
If alignment is made by a laser instrument, please consider the instructions and recommendations provided by
the laser instrument manufacturer.
The alignment should be checked at ambient temperature with machine at operating temperature.
Pulley and belt couplings must be so aligned that the driver pulley center lies in the same plane of the driven
pulley center and the motor shaft and the shaft of the driven machine are perfectly parallel.
After completing the alignment procedures, ensure that mounting devices do not change the motor and
machine alignment and leveling resulting into machine damage during operation.
It is recommended to record the maximum alignment deviation in the Installation Report.
The coupling alignment must be checked periodically.
6.7. CONNECTION OF OIL LUBRICATED OR OIL MIST LUBRICATED MOTORS
When oil lubricated or oil mist lubricated motors are installed, connect the existing lubricant tubes (oil inlet and
oil outlet tubes and motor drain tube), as shown in Figure 6.12. The lubrication system must ensure continuous
oil flow through the bearings as specified by the manufacturer of the installed lubrication system.
Inlet
Drain
Outlet
Figure 6.12
- Oil supply and drain system of oil lubricated or oil mist lubricated motors
6.8. CONNECTION OF THE COOLING WATER SySTEM
When water cooled motors are installed, connect the water inlet and outlet tubes to ensure proper motor
cooling. According to item 7.2, ensure correct cooling water flow rate and water temperature in the motor
cooling system.
6.9. ELECTRICAL CONNECTION
Consider the rated motor current, service factor, starting current, environmental and installation conditions,
maximum voltage drop, etc. to select appropriate power supply cables and switching and protection devices.
All motors must be installed with overload protection systems. Three-phase motors should be fitted with phase
fault protection systems.
Before connecting the motor, check if the power supply voltage and the frequency comply with the
motor nameplate data. All wiring must be made according to the connection diagram on the motor
nameplate. Please consider the connection diagrams in the Table 6.2 as reference value.
To prevent accidents, check if motor has been solidly grounded in accordance with the applicable standards.
Page 156
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...