Engineering: JC/GS/ML
Page 1 of 4
Inc.
seepex
Inc.
511 Speedway Drive
Enon, OH 45323
Phone (937) 864-7150
Fax (937) 864-7157
[email protected]
www.seepex.com
Data Sheet
835294-835296 Page 1
seepex
date
04/24/2013
commission no.
835294-835296
customer
W.M. Lyles
seepex job no.
2115517
offer/item:
5383/0167 item 4 Amend. 1
project
PO#
T1113-20
3 of
seepex progressive cavity pump
type BN 5-12 / A6-A7-A7-H0-IE-X
X=08E4,
20A7
conveying product
U/495/CH
denomination
active dilute polymer
rate of solids
<0.5%
viscosity
ass. <500 cPs
size of solids
no advice
pH-value
ass.
5-9
specific gravity
ass.
1.0
temperature
32 to 113
F
composition
no
advice
remarks
thickening polymer feed pumps
performance data
nom.
min
max
conveying capacity
12
24
GPM
pump speed
225
417
rpm
press in press. branch
104
104
psi
press in suct. branch
Assumed Flooded
differential pressure
104
psi
operating
torque
36
lb. ft.
required drive power
3.59
Hp
starting
torque
60
lb. ft.
remarks
Data according to Performance Curve
technical pump data
range
BN
kind of install.
horizontal
size
5
direction of rot.
counterclockwise
pressure stage
12
pos. of branch
2 @ pos. 3
1 @ pos. 2
component
material design/option
lantern
grey
cast
iron
GG25
standard
suction casing
1.4408
/AISI
316
SS
standard
½”
NPT
gauge
ports
suction connection
DN 3” ANSI B16.5 150 lb. FF
pressure branch
1.4571 / AISI 316 SS
½” NPT gauge ports
pressure connection
DN 3” ANSI B16.5 150 lb. FF
joint
standard standard
grease
30322
high
temp
joint seal
FPM
standard
coupling rod
1.4571
/
AISI
316Ti
standard
rotor
1.4571 / AISI 316Ti
standard
stator
FPM
standard
mechanical seal
1.4408 / AISI 316 SS
Double Acting Mechanical Seal
seal
Chesterton
280
Double
Seal
45MM
316/SC/SC/CBN/SC/Alfas
plug-in shaft
1.4571
/
AISI
316Ti
drilled
30x55
special designs
Page 25
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...