bvo_manual FM Rev. 5/25/06
BVO Model Number Information
Range
GPM Water
Fittings
NPT
Pressure Loss
@ Max Flow
PSIG
Model Number
Brass
304 SS
0.1-1.0
1/4”
0.9
BVO-6102
BVO-6202
0.2-2.0
1/4”
1.4
BVO-6106
BVO-6206
1.0-5.0
1/2”
1.1
BVO-6116
BVO-6216
1.0-13
1”
2.1
BVO-6150
BVO-6250
Option Suffix “U” SPDT switch in place of the N/O switch
Installation Precautions
User's Responsibility for Safety:
it is the user's responsibility
to select the instrument that is appropriate for the application, to
install it per these installation instructions, to perform tests of
the installed system, and to maintain all components. The
failure to do so could result in property damage or serious
injury.
Temperature and Pressure:
The BVO is designed for use in
application temperatures from -10 to 212°F, and pressures to
145 PSIG. Operation outside these limitations will cause
damage to the unit and possible personal injury.
Flammable, Explosive and Hazardous Applications:
The
switch provided with the BVO is not of an explosion proof
design. If the unit is to be used in an area where risk of
explosion exists, the switch must be connected via an
appropriately selected and installed intrinsic safety barrier.
Material Compatibility:
Check your model number with the
wetted materials specification. Make sure that the model
which you have selected is chemically compatible with the
application liquids.
Proper Installation and Handling:
Use a proper sealant with
all installations. Never overtighten the unit within the fitting.
Never use the housing to thread the unit into its fitting
.
Always use only an appropriate sized wrench on the hex
portion of the body. Ensure that the piping is rigidly supported
at the inlet and outlet of the meter. Always check for leaks
prior to system start-up.
Make a Fail-safe System:
Design a fail-safe system that
accommodates the possibility of switch failure as well as
operator error. In critical applications, KOBOLD recommends
the use of redundant backup systems and alarms in addition
to the primary system.
Specifications
Accuracy:
±12% of full scale
Repeatability:
±2% of full scale
Media:
Water-like liquids
Fittings:
NPT
Wetted Parts:
Brass Meters:
Nickel-Plated Brass,
NBR
, Glass
SS Meters:
304 SS,
FKM
, Glass
Temperature Range:
-10 to 212°F
Maximum Pressure:
145 PSIG
Flow Direction:
Vertical, flow bottom to top
N/O Switch Specifications:
Max. Voltage
:
240 VAC, 200 VDC
Max. Current:
1.5 Amp AC, 1.0 Amp DC
Max. Power:
50 VA, 50 Watts
Switching Hysteresis:
4-8 mm of float travel
SPDT Switch Specifications:
Max. Voltage:
240 VAC
Max. Current:
0.8 Amp AC
Max. Power:
30 VA
Switching Hysteresis:
4-8 mm of float travel
BVO Series
Flowmeter and Switch
Installation Instructions
KOBOLD Instruments Inc.
1801 Parkway View Drive
Pittsburgh, PA 15205
1-412-788-2830
Fax: 1-412-788-4890
www.koboldusa.com
Page 205
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...