92
Assembly and Operating Instructions – Gear Units R..7, F..7, K..7, K..9, S..7, SPIROPLAN® W
6
Inspection/maintenance for the gear unit
Inspection/Maintenance
6.6.3 B: Helical, parallel-shaft helical, SPIROPLAN
®
gear units without oil level plug with cover plate
Checking the oil
level via cover
plate
For gear units without oil level bore, the oil level is checked via the cover plate opening.
Proceed as follows:
1. Observe the notes in section "Preliminary work regarding gear unit inspection/main-
tenance" (page 85).
2. For the cover plate to be on top, you have to set up the gear unit in the following
mounting position.
– R07 - R57 in M1 mounting position
– F27 in M3 mounting position
– W10 - W30 in M1 mounting position
3. Loosen the screws [1] of the cover plate [2] and remove the cover plate [2] and the
corresponding gasket [3] (see following figure).
4. Determine the vertical distance "x" between oil level and sealing surface of the gear
unit housing (see following figure).
18643211
18646283
[1]
[2]
[3]
90°
X
Page 104
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...