4
4.
Attach the gauge or other pressure
element to a stinger fitting as shown in
figure 2.
5.
Attach the gauge and stinger fitting
assembly to the fill tool adapter as
shown in figure-2
6.
Turn on the vacuum pump.
7.
Open the vacuum valve.
8.
Allow 5 minutes for the pump to
evacuate the system.
9.
Close both valves.
10.
Turn off the vacuum pump.
Figure 2
11.
Allow the system to sit for 2 minutes.
Check the vacuum gauge to make sure
that there are no leaks in the system.
a.
If the system does not hold
vacuum, check your fitting
connections and start over.
b.
If the system holds vacuum,
proceed to the next step.
12.
Slowly open the oil feed valve. Allow
at least 3 minutes to allow the silicone
oil to flow into the gauge assembly.
13.
Close both valves
14.
Disconnect the stinger fitting from the
fill tool adapter.
15.
The gauge assembly is now ready to
connect to a diaphragm seal.
Figure 3
Page 187
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...