B-Series Switches – Pressure, Differential Pressure,
Temperature & Hydraulic
BULLETIN SW10
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: [email protected] • www.ashcroft.com
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2007 10/08
B-SERIES PRESSURE AND DIFFERENTIAL PRESSURE SWITCH MODEL NUMBER:
To specify the exact switch desired, select entries from appropriate tables as shown in example below.
B 4
2
0
B
X P K
600 PSI
1
2
3
4
5
1 – ENCLOSURE
Pressure switch, Type 400, watertight enclosure
B4
meets NEMA 3, 4, 4X, 13 and IP66 requirements.
Pressure switch, Type 700, explosion-proof
B7
enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66
requirements.
Differential pressure switch, Type 400, water-
D4
tight enclosure meets NEMA 3, 4, 4X, 13 and
IP66 requirements.
Differential pressure switch, Type 700, explosion-
D7
proof enclosure meets Div. 1 & 2, NEMA 7, 9 and
IP66 requirements.
2 – SWITCH ELEMENT SELECTION
Order
Switch Elements
Code
UL/CSA Listed SPDT
20
(7)
Narrow deadband ac
15A, 125/250 Vac
21
Ammonia service
5A, 125/250 Vac
22
(6)
Hermetically sealed switch,
5A, 125/250 Vac
narrow deadband
23
Heavy duty ac
22A, 125/250 Vac
24
(1)
General purpose
15A, 125/250/480 Vac
1
⁄
2
A, 125 Vdc
1
⁄
4
A, 250 Vdc; 6A, 30 Vdc
25
(2)
Heavy duty dc
10A, 125 Vac or dc,
1
⁄
8
HP, 125 Vac or dc
26
(7)
Sealed environment proof
15A, 125/250 Vac
27
High temperature 300°F
15A, 125/250 Vac
28
(5)
Manual reset trip on
15A, 125/250 Vac
increasing
29
(5)
Manual reset trip on
15A, 125/250 Vac
decreasing
31
Low level (gold) contacts
1A, 125 Vac
32
Hermetically sealed switch,
11A, 125/250 Vac
general purpose
5A, 30 Vdc
42
Hermetically sealed switch,
1A, 125 Vac
gold contacts
50
Variable deadband
15A, 125/250 Vac
UL/CSA Listed Dual (2 SPDT)
61
(7)
Dual narrow deadband
15A, 125/250 Vac
62
(7)
Dual sealed environment
15A, 125/250 Vac
proof
63
Dual high temp. 300°F
15A, 125/250 Vac
64
Dual general purpose
15A, 125/250/480 Vac
1
⁄
2
A, 125 Vdc
1
⁄
4
A, 250 Vdc
65
Dual ammonia service
5A, 125/250 Vac
67
(4,6)
Dual hermetically sealed
5A, 125/250 Vac
switch, narrow deadband
68
(4)
Dual hermetically sealed
11A, 125/250 Vac
switch, general purpose
5A, 30 Vdc
70
Dual low level gold contacts
1A, 125 Vac
71
(4)
Dual hermetically sealed
1A, 125 Vac
switch, gold contacts
3 – ACTUATOR SEAL
Range
Code
Process
and
Temperature
Vac.
0-600
1000
3000
Material
Limits °F
(9)
˝ H
2
O
psi
psi
psi
B – Buna-N
0 to 150
•
•
•
•
V – Viton
20 to 300
•
•
•
T – Teflon
0 to 150
•
•
•
•
S – 316L
(8)
0 to 300
•
•
P – Monel
(8)
0 to 300
•
•
4 – OPTIONS
Use table from page 6
5 – RANGE
Select from table on page 4
NOTES:
1 Standard switch.
2 Not available with psid ranges.
3 Dual switches are 2 SPDT snap-action switches, not independently
adjustable.
4 Wires cannot be terminated inside B400 switch enclosure.
5 Not available with type 700 enclosure.
6 Estimated dc. rating, 2.5A, 28 Vdc (not
UL listed).
7 Estimated dc rating, 0.4A, 120 Vdc (not UL listed).
8 Available on pressure only.
9 Ambient operating temperature limits –20 to 150°F, all styles, setpoint
shift of ±1% of range per 50°F temperature change is normal.
Switches are calibrated at 70°F reference.
Summary of Contents for BN 5-12 Series
Page 13: ...TAB 1 DEVICE DATA SHEETS ...
Page 18: ...TAB 2 APPROVED SUBMITTAL ...
Page 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Page 26: ...Your advantages our pumps ...
Page 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Page 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Page 133: ...Page 37 ...
Page 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Page 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Page 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Page 307: ...R Page 29 ...
Page 308: ...R Page 30 ...