SET.10
of 68
SEL-700G Relay
Instruction Manual
Date Code 20170814
SEL-700G Settings Sheets
Group Settings (SET Command)
Y-Side Residual Time-Overcurrent
(Shown if Slot E = 71/ 75 or Slot Z = 83/87 [700GT, 700GW])
(Hidden if CTCONY := Delta)
RES TOC LEVEL (OFF, 0.50–16.00 A [5 A I
YNOM
], 0.10–3.20 A [1 A I
YNOM
])
51GYP :=
RES TOC CURVE (U1, U2, U3, U4, U5, C1, C2, C3, C4, C5)
(Hidden if 51GYP := OFF)
51GYC :=
RES TOC TDIAL (0.50–15.00 [if 51G_C := U_], 0.05–1.00 [if 51G_C := C_])
(Hidden if 51GYP := OFF)
51GYTD :=
EM RESET DELAY (Y, N) (Hidden if 51GYP := OFF)
51GYRS :=
CONST TIME ADDER (0.00–1.00 s) (Hidden if 51GYP := OFF)
51GYCT :=
MIN RESPONSE TIM (0.00–1.00 s) (Hidden if 51GYP := OFF)
51GYMR :=
RES TOC TRQCTRL (SEL
OGIC
) (Hidden if 51GYP := OFF)
51GYTC :=
Y-Side Negative-Sequence Time-Overcurrent
(Shown if Slot E = 71/73/ 75/ 77 [700GT, 700GW])
NSEQ TOC LEVEL (OFF, 0.50 to 16.00 A [5 A I
YNOM
], 0.10 to 3.20 A [1 A I
YNOM
])
51QYP :=
NSEQ TOC CURVE (U1, U2, U3, U4, U5, C1, C2, C3, C4, C5)
(Hidden if 51QYP := OFF)
51QYC :=
NSEQ TOC TDIAL (0.50 to 15.00 [if 51Q_C := U_], 0.05 to 1.00 [if 51Q_C := C_])
(Hidden if 51QYP := OFF)
51QYTD :=
EM RESET DELAY (Y, N) (Hidden if 51QYP := OFF)
51QYRS :=
CONST TIME ADDER (0.00 to 1.00 s) (Hidden if 51QYP := OFF)
51QYCT :=
MIN RESPONSE TIM (0.00 to 1.00 s) (Hidden if 51QYP := OFF)
51QYMR :=
NSEQ TOC TRQCTRL (SEL
OGIC
) (Hidden if 51QYP := OFF)
51QYTC :=
Neutral Time-Overcurrent
(Hidden if Slot Z = 83/87 [700GW])
NEUT TOC LEVEL (OFF, 0.50–16.00 A [5 A I
NNOM
], 0.10–3.20 A [1 A I
NNOM
])
51NP :=
NEUT TOC CURVE (U1, U2, U3, U4, U5, C1, C2, C3, C4, C5)
(Hidden if 51NP := OFF)
51NC :=
NEUT TOC TDIAL (0.50–15.00 [if 51N_C := U_], 0.05–1.00 [if 51N_C := C_])
(Hidden if 51NP := OFF)
51NTD :=
EM RESET DELAY (Y, N) (Hidden if 51NP := OFF)
51NRS :=
CONST TIME ADDER (0.00–1.00 s) (Hidden if 51NP := OFF)
51NCT :=
MIN RESPONSE TIM (0.00–1.00 s) (Hidden if 51NP := OFF)
51NMR :=
NEUT TOC TRQCTRL (SEL
OGIC
) (Hidden if 51NP := OFF)
51NTC :=
X-Side Directional Elements
(Hidden if Slot Z = 83/84/87/88)
DIR CONTROL ENBL (Y, AUTO, N)
EDIRX :=
(All X-Side Directional Elements settings are hidden if EDIRX := N)
FWD DIR ON LOP (Y, N)
EFWDLOPX:=
POS SQ LN Z MAG (0.10–510.00 ohm [5 A I
XNOM
],
0.50–2550.00 ohm [1 A I
XNOM
])
Z1MAGX :=
POS SQ LN Z ANG (50.00–90.00°)
Z1ANGX :=
Summary of Contents for SEL-700G Series
Page 14: ...This page intentionally left blank ...
Page 22: ...This page intentionally left blank ...
Page 32: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 106: ...This page intentionally left blank ...
Page 510: ...This page intentionally left blank ...
Page 560: ...This page intentionally left blank ...
Page 578: ...This page intentionally left blank ...
Page 588: ...This page intentionally left blank ...
Page 604: ...This page intentionally left blank ...
Page 634: ...This page intentionally left blank ...
Page 738: ...This page intentionally left blank ...
Page 802: ...This page intentionally left blank ...