HandKey II Manual
41
Set LED/Beeper lets you control the beeper and
LEDs.
•
Enable Beeper:
When on, the reader beeps
once when you press a key, once when a user
is granted access, and twice when access is
denied.
•
External LED Control
determines what controls
reader’s LED display. If this is set to No, the LED
is normally red, turns amber when user input is
required, and turns green when an ID is verified.
If this is set to Yes, the LEDs are controlled by
input from your access control panel; the red
LED is on when input is received through the
terminal connector block (P3) pin 8, green is on
when input is received through pin 9, and amber
is on when input is received through both 8 and
9. See page 11 for more on what each terminal
connector block pin is for.
•
External Bell Control:
If this is set to Yes, the
beeper sounds when input is received from your
access control panel through terminal connector
block (P3) pin 7. See page 11 for more on what
each terminal connector block pin is for.
If all of your users have the same length ID:
Set
ID Length lets users type ID numbers without
having to press enter at the end. For example, if all
user IDs were four digits long, you could set the ID
length to 4 and the reader would automatically
continue when the user enters the fourth digit.
If your IDs are different lengths:
Set the ID length
to the length of the longest ID. Users with the
longest IDs won’t have to press enter; users with
shorter IDs will.
If IDs are entered from a card reader:
What you
enter here doesn’t matter; Set ID Length doesn’t
affect what length IDs are accepted from a card
reader; that is determined by the input formats you select; see page 53.
The length is initially set to 25 digits (the longest possible Wiegand ID). Valid values are
from 1 to 25 digits.
Set Language lets you change the language used
for the reader’s display. This is initially set to
English. Other languages will be supported in the
future.
Controlling the
Beeper and
LEDs
SET BEEPER
*BACK #NEXT
To change this setting, press enter.
You’ll see:
ENABLE BEEPER
*NO #YES
Type * (No) to disable the beeper.
Type # (Yes) to enable the beeper.
You’ll see:
EXTERNAL LED
CONTROL
*NO #YES
Type * for No or # for Yes. You’ll see:
EXTERNAL BELL CNTRL
*NO #YES
Type * for No or # for Yes. To return to
the Setup menu, press CLEAR.
Setting the ID
Length
SET ID LENGTH
*BACK #NEXT
To change this setting, press enter.
You see:
INPUT LENGTH
Type the length of the longest ID
you will use (valid lengths: 1-15)
and press enter. To leave the length
unchanged, press enter without
typing anything.
Setting the
Language for
the Reader’s
Display
SET LANGUAGE
*BACK #NEXT
To change this setting, press enter.
You see:
SET ENGLISH
*NO #YES
You currently can’t choose any other
option.