Preliminary
I/O PORTS
S3C2451X RISC MICROPROCESSOR
11-40
EXTINTn (External Interrupt Control Register n) (Continued)
EXTINT2 Bit
Description
Reset
Value
FLTEN17
[7]
Filter enable for EINT17
0 = Filter Enable
1= Filter Disable
0
EINT17 [6:4]
Setting
the
ٛ
signalling method of the EINT17.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
000
FLTEN16
[3]
Filter enable for EINT16
0 = Filter Enable
1= Filter Disable
0
EINT16 [2:0]
Setting
the
ٛ
signalling method of the EINT16.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
000