4. Troubleshooting
4.6.3. Horizontal periodic Black Band or Dot
A. Typical faulty images
B. Troubleshooting procedure
Step
Cause
Action
1
Horizontal periodic dot. (CR, 37.7mm)
•
The surface of the charge roller(CR) is
contaminated.
•
CR is scratched.
Wipe the surface of contaminated part with a soft cloth
and alcohol.
Replace the Drum unit.
(Refer to 3.3.2.1.)
2
Horizontal periodic black band.(CR, 37.7mm)
•
CR is inferior in quality.
Replace the Drum Unit.
(Refer to 3.3.2.1.)
3
OPC is damaged.
Replace the Drum Unit.
(Refer to 3.3.2.1.)
Copyright© 1995-2016 SAMSUNG. All rights reserved.
4-210