4. Troubleshooting
Unit
Item
Max. Life
Default
Threshold
Yellow
300K
10%
5 ~ 30%
Magenta
300K
10%
5 ~ 30%
Cyan
300K
10%
5 ~ 30%
Developer Unit
Black
300K
10%
5 ~ 30%
Waste Toner Container
Waste Toner Container
50K
Near Full
NA
Finisher
Finisher Stapler
Cartridge
NA
Near Empty
NA
ITB
300K (PM Count)
5%
2% ~ 10%
ITB Cleaner
150K (PM Count)
5%
3% ~ 10%
ITB
T2 Roller
150K (PM Count)
5%
3% ~ 10%
Fuser
Fuser
150K (PM Count)
10%
5% ~ 20%
P/up Roller MP
200K (PM Count)
10%
5% ~ 20%
P/up Roller Kit-tray1
200K (PM Count)
10%
5% ~ 20%
P/up Roller Kit-tray2
200K (PM Count)
10%
5% ~ 20%
P/up Roller Kit-tray3
200K (PM Count)
10%
5% ~ 20%
Roller
P/up Roller Kit-tray4
200K (PM Count)
10%
5% ~ 20%
DADF Roller
Assembly ADF Roller
200K (PM Count)
10%
5% ~ 20%
4.4.3.3. Software Version
•
Information > Software Version
This menu displays all the version of the software installed in the system in detail.
4.4.3.4. Service Hours
•
Information > Service Hours
This menu displays three items, “Power on Hours”, “Low Power Hours” and “Power Save Hours”.
-
Power on Hours : It indicates the hours of system power on since the first booting of the system.
-
Low Power Hours : It indicates the hours of system low power on since the first booting of the system.
-
Power Save Hours : It indicates the hours of system power save since the first booting of the system.
4.4.3.5. Fault Log
•
Information > Fault Log
This menu displays faults occurred while the system was operating.
Pressing clear button will clear all the save fault log of the system.
Copyright© 1995-2016 SAMSUNG. All rights reserved.
4-16