4. Troubleshooting
•
Diagnostics > Image Management > Auto Tone Adjustment Activation > Full
Purpose
To correct image quality when any OPC drum is replaced or the life of the OPC drum is changed.
replacing any OPC drum or density of the image is poor. And this function will be performed when
temperature and/or humidity in the room changes suddenly.
Operation Procedure
Change execution condition(s) of Normal TRC Control.
•
On : Full TRC Control Enable
•
Off : Full TRC Control Disenable
Verification
Print out a test job and make sure the image quality has recovered.
Specification
N/A
Reference
Refer to 4.6.6 Light Image
Copyright© 1995-2016 SAMSUNG. All rights reserved.