103-0031 Regi Curl Length
Buckle Control : Regi On Curl
0
6 / -3
103-0032 Duplex Regi Curl Length
Buckle Control : Duplex Regi On Curl
(x1)
0
6 / -3
103-0033 Double Speed Duplex Regi Curl Length
Buckle Control : Duplex Regi On Curl
(x2)
0
6 / -3
109-0000 StandBy Temperature offset
Target Temperature during standby mode.
0
5 / -5
109-0010 Run Temperature offset
Target Temperature during run mode.
0
5 / -5
109-0050 60 gms Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0060 90 gms Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0070 Bond Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0090 Cardstock Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0100 Envelopes Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0110 Labels Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0130 Thick Temperature Offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0131 Recycled Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0132 Special Temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0133 1200 dpi_thin temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0134 1200 dpi_plain temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0135 1200 dpi_thick temperature offset
Media type offset for fuser roll temperature.
0
5 / -5
109-0140 Cooldown Mode idling Time1
Narrow Paper idling Time1(~175
℃
)
10
150/0
109-0150 Cooldown Mode idling Time2
Narrow Paper idling Time2(~185
℃
)
30
150/0
109-0160 Cooldown Mode idling Time3
Narrow Paper idling Time3(~195
℃
)
60
150/0
109-0170 Cooldown Mode idling Time4
Narrow Paper idling Time4(~205
℃
)
90
150/0
109-0180 Cooldown Mode idling Time5
Narrow Paper idling Time5(205~
℃
)
120
150/0