Note
1. Flat
washer
2. Nut
3. Spring
washer
4. Flat
washer
When using a stiff cable, fix it near the cable lug to avoid stress on the lug and cable.
Do not use self-tapping screws to fasten terminals.
Bundle cables of the same type and running in the same direction into groups. Keep cables clean and straight.
Cables shall be tied according to the following table.
Diameter of Cable Bundle (mm)
Space between Bundles (mm)
10
80 to 150
10 to 30
150 to 200
30
200 to 300
Do not tie knots for cables or cable bundles.
The metal parts of the cold-pressed terminal blocks, such as air circuit breakers, shall not be exposed outside of the
blocks.