MTBF 403,000
hours
Weight
Net weight: 3.2 kg
Dimensions
(W x D x H)
399 mm x 440 mm x 40.18 mm
RG-WALL 1600-B-ED
Module Appearance
Figure 0-30 Appearance of the
RG-WALL1600-B-ED Module
External Port
It provides two SFP+ ports. The SFP+ ports support 10G SFP+ modules and Gigabit SFP modules. Hot swapping of the
RG-WALL1600-B-ED
, SFP and SFP+ modules is supported.
The
RG-WALL1600-B-ED
supports 10G SFP+ and Gigabit SFP modules. 10G SFP+ modules cannot be
used as Gigabit SFP modules.
LED
LED
Identification
on the panel
Status
Meaning
Off
The module is NOT receiving power.
Solid red
The module is faulty.
Solid yellow
High temperature alarm. The system keeps operating
but the performance is affected.
Blinking
green
Initialization is in progress. Continuous blinking
indicates errors.
System LED
Status
Solid green
The module is operational
Off
The port link is NOT connected.
Solid green
The port is connected.
SFP+ port LED in switching
mode
Link/ACT
Blinking
The port is transmitting and receiving data.
Specifications
Model
RG-WALL1600-B-ED
CPU: Quad-core CPU, each core with the clock speed of 1.0G
BOOTROM
: 8 MB
Flash Memory
: 512 MB
Management CPU
SDRAM : DDRIII 1 GB
CPU: 32-core CPU, each core with the clock speed of 1.2G
BOOTROM
: 8 MB
Flash Memory
: 512 MB
Service CPU
SDRAM : DDRIII 8 GB
Port Type
Two SFP+ ports, supporting 10G SFP+ modules and gigabit SFP modules
Transmission
Medium
1000BASE-SX (850nm)
Multi-mode optical fiber
1000BASE-LX (1310nm)
Single-mode optical fiber
1000BASE-LH (1310nm) Single-mode optical fiber
1000BASE-ZX (1550nm)
Single-mode optical fiber
10GBASE-SR (850nm)
Multi-mode optical fiber
10GBASE-LR (1310nm)
Single-mode optical fiber
Summary of Contents for RG-S8605E
Page 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Page 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Page 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Page 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Page 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Page 132: ......