LED
IN
OUT
Meaning
Solid green
Solid green
The module is operational
Solid green
Solid red
There is external power supply. The power module is not in
use.
Off Solid
red
There is no external power supply. The power module is in
use.
Off Solid
red Overcurrent
Solid green
Solid red
Output overcurrent protection
Solid green
Solid orange
Temperature alarm
Solid green
Solid red
Over-temperature protection
Solid green
Solid red
PSR on/off
Solid green
Solid red
Phase loss protection
Solid green
Solid red
Fan failure
Specifications
Module Model
RG-PD600I
Rated Voltage
Range
-48 VDC
Max Voltage
Range
-40 to -75 VDC
Max Power
Output
600 W
Weight
Net weight: 1.30 kg
Power Cord
Requirement
20A power cord
Please connect the power cord to the corresponding terminal according to the color and then tighten the
screws.
Operation altitude: 2000m max. Storage altitude: 2000m max.