Figure 3-40 Installing the QSFP+ Module Equipped with a Pull Tap
3)
Use the fiber optical patch cord to connect the 40G QSFP+ module to the fiber optical network. Select the patch cord
with the connector corresponding to the port.
4)
After the patch cord is connected, the Link/ACT Status LED is on. Otherwise, please check connection of the patch
cord.
Precaution
Pay attention to the proper end of the QSFP+ module for installation. If the QSFP+ module cannot be inserted to the
end, do not push it forcefully. Please try the other end of the module.
It is recommended that you do not remove the protective rubber plug from QSFP+ module before connecting fibers.
It is recommended that you do not insert the QSFP+ module with a fiber into the slot. Unplug the fiber before
installing the module.
Do not touch the connecting finger on the module.
Do not squeeze, bend or fold the optical fiber, which may cause system performance degradation or data loss.
Installing 40-Gigabit QSFP+ Cables
To avoid damaging components due to operation errors, read this section carefully before installing
40-Gigabit QSFP+ copper cables.
Take the following steps to install 40-Gigabit QSFP+ copper modules:
1)
You can install the QSFP+ copper module with power on. Hold the connector of a copper cable module with one
hand and carry the cable to the front panel of the switch with the other. Push the module gently into the QSFP+
module slot until you hear a click, indicating the module is correctly installed.
Figure 3-41 Installing the QSFP+ Copper Module
Summary of Contents for RG-S8605E
Page 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Page 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Page 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Page 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Page 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Page 132: ......