Figure 3-43 Connecting the Power Cord
Please use the 3-pin power cord. The cross-sectional area of each pin is 1.5 mm
2
or 14 AWG minimum.
16A and 10A power cords are available for the RG-S8605E,
RG-S8607E and RG-S8610E
AC power supply.
Adopt the proper socket and verify the AC power supply capacity in the machine room.
Connect the power cord to the location as required according to the identification on the DC power module panel,
including
RG-PD1600I and RG-PD600I.
1)
Take out the DC power module and power cord. Insert the DC power plug into the power module socket.
2) Remove the screws on the grounding terminal of the DC power supply with the screwdriver.
3) Connect the DC power cords according to the instructions on the panel, which are green with yellow strip (ground
wire), blue (-) and red (+) from left to right, as shown in figure 3-44.
4) Fasten the OT terminal of the DC power cord to the connecting terminal with the screwdriver.
Figure 3-44 Power Cord Instruction on Chassis