M8600E-48XS-DB
M8600E-24XS4QXS-DB
M8600E-12QXS-DB
M8600E-24SFP/8GT-EB
M8600E-24GT/8SFP-EB
RG-WALL 1600-B-ED
M8600E-08XS-EF
M8600E-44SFP4XS-EF
M8600E-48GT-EF
Hot Swapping
Supported
Supervisor
Module
Redundancy
Supported
Power Supply
Module
RG-PA1600I: 90 to 180 VAC, power: 1200W;
180 to 264 VAC, power: 1600W
RG-PA600I: 90 to 180 VAC, power: 600W:
180 to 264 VAC, power: 600W
RG-PA1600I-P: 90 to176 VAC, power: 1000W;
176 to 264 VAC, power: 1600W
RG-PA1600I-PL: 90 to 176 VAC, power: 1000W;
176 to 264 VAC, power: 1600W
RG-PA3000I- PL: 90 to 176 VAC, power: 1200W;
176 to 210 VAC, power: 2500W
210 to 264VAC, power: 3000W
RG-PD1600I: -40 to -75 VDC, power: 1400W
RG-PD600I: -40 to -75 VDC power: 600W
HVDC Power
Supply
RG-PA1600I: 192 to 216 VDC, power: 1200W;
216 to 290 VDC, power: 1600W
RG-PA600I: 192 to 290 VDC, power: 600W
The power supply supports reversible HVDC.
The HVDC-supported PDU socket should be provided.
It is recommended to install a DC air switch. During power-on, turn on the DC air
switch after connecting the power cord. During power-off, turn off the DC air switch
before removing the power cord.
Power Supply
Redundancy
The power supply redundancy of the same model is supported.
Fan Module
Three M10-FAN-R modules and one M10-FAN-F module
EMC Standards
GB9254-2008 CLASS A
Safety Standards GB4943-2011
Operating
Temperature
0 to 50°C
Storage
Temperature
-40 to 70°C
Operating
Humidity
10%-90% RH (non-condensing)
Long term operation altitude: 3000m at 50
℃
. The temperature decreases by 1
℃
as the altitude
ranging from 3000m to 4000m increases by each 200m.
Operation altitude: 4000m max
Altitude
Storage altitude: 4000m max
MTBF 259,000
hours
Noise
67.4 dB at 35
℃
77.4 dB at 50
℃
Weight
Net weight: 103.32 kg (including chassis and fans)
Dimensions
(W x D x H)
442 mm x 776 mm x 797.3 mm (cable management brackets excluded), 18U
442 mm x 836 mm x 797.3 mm (cable management brackets included), 18U
Summary of Contents for RG-S8605E
Page 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Page 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Page 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Page 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Page 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Page 132: ......