Is the media loaded?
The media heating system does not warm up to the set temperature when [SETUP] is off (by default). Load the
media and wait for the machine to warm up.
RELATED LINKS
P. 83 "Adjusting the Ink-drying Method"
Is HEATER CONFIG set to OFF?
Even if you set the print heater temperature in the batch settings for printing (the MEDIA SETTING menu), if
"POWER" under HEATER CONFIG is set to "OFF," the media heating system will not warm up. Set "POWER" under
HEATER CONFIG to "ON."
RELATED LINKS
P. 90 "Switching Off the Print Heater and Dryer Together"
Is the temperature of the room too low?
The media heating system may not warm up sufficiently when the ambient temperature is less than 20°C (68°F).
Also, even when the media heating system reaches its set temperatures, adequate effectiveness may not be appa-
rent if the media is thoroughly chilled. Before printing, allow the media to come to room temperature.
The Media Heating System Doesn't Warm Up