10.
Press [
◀
] or [
▼
] to display the screen shown below.
CALIBRATION
TEST PRINT
11.
Press [ENTER].
Printing of the test pattern starts.
12.
Check the test pattern to see whether the correction was successful.
Check that the gap and overlap are the smallest for the figure indicated by "
" (that is, the current cor-
rection value). If the gap and overlap are smaller for another figure, set the correction value again.
13.
When you have successfully performed the correction, press [MENU] to go back to the original screen.
MEMO
Depending on the software RIP you are using, you can also configure this setting in the software RIP (by, for example,
choosing the media type). When you have made the setting in the software RIP, the software RIP's setting is used and the
printer's setting is ignored.
Using the Correction Functions
1. Optimizing the Output Quality
73
Summary of Contents for TrueVIS VF2-640
Page 7: ...1 Basic Handling Methods 6...
Page 51: ...Ink Pouch TR2 Cleaning Liquid Pouch Replacement 50 2 Basic Operations...
Page 52: ...2 Output Method 51...
Page 61: ...REDO ADJ YES DONE 10 Press ENTER to confirm your entry Printing Output 60 1 Printing Method...
Page 68: ...3 Optimizing Quality and Effi ciency 67...
Page 99: ...W1100mm B Adjusting the Output start Location 98 2 Optimizing Work Efficiency...
Page 121: ...4 Maintenance 120...
Page 169: ...5 Troubleshooting Methods 168...
Page 196: ...6 Appendix 195...