![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 300](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982300.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
285
User Manual 1409.5570.32 ─ 05
Example:
EBOX:USER:SSI:SIZE 12
sets the word size resolution to 12 bit.
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:SSI:SPI:CLOCk:FREQuency
<Frequency>
Selects the system clock frequency.
Parameters:
<Frequency>
1MHZ | 2.5MHZ | 5MHZ | 8.333MHZ | 12.5MHZ | 25MHZ
*RST:
1MHZ
Example:
EBOX:USER:SSI:SPI:CLOC:FREQ 12.5MHz
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:SSI:SPI:CLOCk:PHASe
<Phase>
Selects the phase of the clock signal. Either 0 or 180 degree are possible.
Parameters:
<Phase>
0 | 180
*RST:
0
Example:
EBOX:USER:SSI:SPI:CLOC:PHAS 180
shifts the phase of the clock signal by 180 degree.
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:SSI:SPI:CSELect
<CSelect>
Selects the SSI-SPI chip.
Parameters:
<CSelect>
0 | 1 | OFF | ON
*RST:
0
Example:
EBOX:USER:SSI:SPI:CSEL ON
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:SSI:SPI:FSELect
<FSelect>
Selects a SSI:SPI file.
Parameters:
<FSelect>
string
Example:
EBOX:USER:SSI:SPI:FSEL "spidata"
Manual operation:
See
User Defined - Remote Control Commands
Summary of Contents for EX-IQ-BOX
Page 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...
Page 391: ......