![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 104](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982104.webp)
R&S EX-IQ-BOX Configuration
R&S
®
EX-IQ-BOX
89
User Manual 1409.5570.32 ─ 05
Fig. 6-22: R&S
EX-IQ-BOX Data Setup and Clock Setup dialogs
The "Data Setup" dialog enables to define the mode for data transmission. The cur-
rently set bits alignment at the user interface is indicated graphically.
The "Clock Setup" dialog contains all clock settings required for User Defined proto-
cols. The lower area indicates clock and data signal direction in a block diagram
6.2.1.4
I/Q Data Transmission
Signal transmission starts when you turn on the "Status" in the
Baseband Input / Digital
I/Q Output
settings dialogs.
6.2.2 R&S Signal Analyzers
The information in this section applies to R&S FSx and R&S FMU Signal Analyzers.
The R&S
EX-IQ-BOX "1409.5502.02" can be controlled directly by an R&S signal ana-
lyzer in a "User Defined" application. Test cases of standardized protocols require
R&S
DigIConf.
An R&S signal analyzer must be equipped with the digital baseband interface option R&S
FSQ-B17. The R&S
EX-IQ-BOX is then connected to this digital interface.
The R&S
EX-IQ-BOX is connected either only to the R&S signal analyzer, or additionally
to a PC.
The configuration is performed in the signal analyzer´s configuration dialogs. Accessing
the dialogs is described in
, on page 92 and the settings in
Configuration via R&S Instruments