SOURce:RECeiver:CLOCk:RATE
<Rate>
[:SOURce<hw>]:EBOX:USER:CLOCk:RATE
<Rate>
Sets/queries the clock rate (frequency) for signal transmission between the R&S
EX-IQ-
BOX and the external device (DUT). Depending on the logic type and the clock source
the clock rate range varies).
SCR
DDR
INT
WS
f
f
s
CLK
Fig. 9-1: User defined > Clock rate
f
clk
= clock rate
f
s
= sample rate
WS = Word size
INT = Interleaving mode
DDR = double rata rate
SCR = sample/clock rate ratio
Value range
f
s
=
Sample rate
1 kHz ... 100 MHz
f
clk
==
Clock rate
LVTTL
: 1 (25) kHz - 100 MHz
*)
LVDS
: 1 (25) kHz - 400
MHz*)
WS
==
Word size
4 ... 18 (serial mode)
1 (parallel mode)
Int
==
Interleaving mode
1 (non interleaved)
2 (I/Q and Q/I interleaved)
DDR
==
Double data rate
1 (SDR)
2 (DDR)
SCR
==
Sample/Clock rate
ratio
1, 4/5, 2/5, 1/5, 1/10, 1/20
*)
1 kHz represents the internal clock source, fed in from the R&S Instrument, 25 kHz are given from the
external reference at the user interface.
Note:
The value range of the clock rate depends on
Protocol
,
Logic Type
and
Signal
Type
settings.
Parameters:
<Rate>
float
Range:
1 kHz to 400 MHz
*RST:
10 MHz
Example:
SOUR1:EBOX:USER:CLOC:RATE?
query the current frequency of the clock signal of the R&S
EX-IQ-
BOX.
SOUR1:EBOX:USER:CLOC:RATE 10MHZ
set the clock rate of the R&S
EX-IQ-BOX to 10 MHz.