![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 139](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982139.webp)
Protocol Settings
R&S
®
EX-IQ-BOX
124
User Manual 1409.5570.32 ─ 05
Rx Received Bits
Indicates the number of received bits. This functions consecutively counts the number of
received bits, compares them with the sent data and determines the error rate.
Remote command:
Rx BER
Indicates the bit error rate. The function consecutively counts the number of discrepan-
cies that occur during the test. The BER result is the ratio, which is calculated by dividing
the number of error bits by the total number of bits.
Remote command:
7.1.10 SSI - Serial Synchronous Interface
The "SSI General" panel contains parameters for data transmission of SSI (Serial Syn-
chronuos Interface) signals.
The graphic in the clock dialog of the signal generators and in R&S
DigIConf indicates
the frame configuration, data flow and the control signals Clock, Frame Synchronization
and Data.
Settings of the SSI logic types currently provide special applications and should not be
changed. Extensions for future applications are intended.
Word Size
Defines the size in bits of an I or Q data word. The size is defined from 4 up to 24 bits.
Remote command:
C&M Size
Defines the number of the Control & Management Bits which follows the I/Q data word.
The size is defined from 0 up to 32 bits.
Remote command:
User Defined
Summary of Contents for EX-IQ-BOX
Page 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...