2. Important Safety Information
2-4 Safety information
18 / 168
<Electrical data>
Model
Supply voltage
Power
consumption
Signal output
Option (select one)
No alarm relay/
No digital
communication
Alarm relay
(contact output)/
Resistance load
only
Digital
communication
SD-3RI
24 V DC
(18 V - 30 V
DC Max)
3.8 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DRI
GD-3RI
1.2 W Max
―
―
―
―
SD-3GH
24 V DC
(18 V - 30 V
DC Max)
4.5 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DGH
GD-3GH
2 W Max
―
―
―
―
SD-3GHS
24 V DC
(18 V - 30 V
DC Max)
4.5 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DGHS
GD-3GHS
2 W Max
―
―
―
―
SD-3NC
24 V DC
(18 V - 30 V
DC Max)
4.5 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DNC
GD-3NC
2 W Max
―
―
―
―
SD-3SP
24 V DC
(18 V - 30 V
DC Max)
3.5 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DSP
GD-3SP
1 W Max
―
―
―
―
SD-3EC
24 V DC
(18 V - 30 V
DC Max)
2.8 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DEC
GD-3EC
1 W Max
―
―
―
―
SD-3ECS
24 V DC
(18 V - 30 V
DC Max)
2.8 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DECS
GD-3ECS
1 W Max
―
―
―
―
SD-3ECB
24 V DC
(18 V - 30 V
DC Max)
3.1 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
SD-3DECB
GD-3ECB
1 W Max
―
―
―
―
SD-3SC
24 V DC
(18 V - 30 V
DC Max)
5 W Max
0 - 22 mA + HART
―
30 V DC, 1 A
250 V AC, 2 A
RS-485 output
<Certificate numbers>
IECEx PRE 20.0064 X
Presafe 20 ATEX 69725 X
* The “X” at the end of the certificate number indicates the following special operating conditions:
・
Do not attempt to repair explosion-proof joints.
・
Damage to the window plate due to strong impact may affect explosion-proof performance. The product is
subject to “Low (2J)” explosion-proof conditions, indicating risk of mechanical damage.
・
Avoid rubbing the nameplate area with a dry cloth during use, maintenance, or cleaning. Doing so may result
in a static charge buildup of up to 6 nF.
・
For information on the explosive-proof operating temperature range, refer to <Explosion-proof performance
data> in ‘2-4 Safety information’.
・
If attaching a lightning arrester to the SD-3, apply high-strength thread-locking compound to the mounting
screw.
・
The ATEX compliant models do not support the measuring functions specified in 1.5.5 of Annex II of the
ATEX directive. This directive provides guidelines on the performance of gas detectors and safety devices
and is based on the requirements of related EU harmonized standards.
・
The IECEx models do not support the measuring functions of EUT. These guidelines address the
performance of gas detectors and safety devices.
Summary of Contents for GD-3EC
Page 169: ...11 Appendix Revision History 169 168...
Page 170: ...11 Appendix Revision History 170 168...
Page 171: ...11 Appendix Revision History 171 168...
Page 172: ...11 Appendix Revision History 172 168...
Page 173: ...11 Appendix Revision History 173 168...
Page 174: ...11 Appendix Revision History 174 168...
Page 175: ...11 Appendix Revision History 175 168...