009 Initial TC
*ENG
Adjusts the initial toner concentration.
[1 to 15 / 7 / 0.1 wt%/step]
010 Upper: TC
*ENG
Adjusts the upper limit of the toner concentration.
[1 to 15 / 9.5 / 0.1 wt%/step]
011 Lower: TC
*ENG
Adjusts the lower limit of the toner concentration.
[1 to 15 / 4 / 0.1 wt%/step]
012 Upper Sensitivity
*ENG
Adjusts the upper limit of the TD sensor sensitivity.
[0.2 to 0.5 / 0.44 / 0.001 V/wt% /step]
013 Lower Sensitivity
*ENG
Adjusts the lower limit of the TD sensor sensitivity.
[0.2 to 0.5 / 0.209 / 0.001 V/wt% /step]
014
Toner Density Between H and
M
*ENG
[1 to 10 / 3.5 / 0.1 wt%/step]
015
Toner Density Between M and
L
*ENG
[1 to 10 / 3.5 / 0.1 wt%/step]
3224
[Vtref Correction: Pixel] DFU
Adjusts the coefficient of Vtref correction for each coverage and color.
001 Low Coverage Coefficient: Bk
*ENG
[0 to 5 / 1 / 0.1 /step]
002 Low Coverage Coefficient: M
*ENG
003 Low Coverage Coefficient: C
*ENG
004 Low Coverage Coefficient: Y
*ENG
005 High Coverage Coefficient: Bk
*ENG
[0 to 5 / 1 / 0.01 V/step]
006 High Coverage Coefficient: M
*ENG
[0 to 5 / 0.5 / 0.01 V/step]
007 High Coverage Coefficient: C
*ENG
008 High Coverage Coefficient: Y
*ENG
009 Low Coverage: Threshold
*ENG
Adjusts the threshold of the low
coverage.
[0 to 20 / 3 / 0.1 %/step]
System Service Mode
261
8
Summary of Contents for MPC 2800 AT-C2
Page 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Page 2: ......
Page 16: ...Overview Component Layout 1 Product Information 14 1...
Page 152: ...2 Installation 150 2...
Page 156: ...3 Preventive Maintenance 154 3...
Page 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Page 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Page 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Page 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Page 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Page 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Page 327: ...Controller Self Diagnostics 325 5...
Page 354: ...MEMO 352...
Page 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Page 356: ......
Page 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Page 360: ...4...
Page 396: ...2 Appendix Maintenance Tables 40 2...
Page 474: ...4 Appendix Process Control Error Conditions 118 4...
Page 476: ...5 Appendix Troubleshooting Guide 120 5...
Page 484: ...5 Appendix Troubleshooting Guide 128 5...
Page 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Page 500: ...7 Appendix Electrical Component Defects 144 7...
Page 854: ...MEMO 498...
Page 855: ...MEMO 499...
Page 856: ...MEMO 500 EN...