No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
554
A
Pressure roller fusing lamp overheat (hardware error)
The pressure roller thermistor detects 250°C or more.
• Defective PSU
• Defective IOB
• Defective BICU
• Defective fusing control system
1. Replace the pressure roller thermistor.
2. Replace the PSU.
3. Replace the IOB.
4. Replace the BICU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
555
A
Pressure roller lamp consecutive full power 2
When the fusing unit is not running in the ready condition, the pressure roller-fusing
lamp keeps ON full power for 8 seconds or more.
• Broken pressure roller fusing lamp
Related SC code: SC 545
1. Replace the pressure roller fusing lamp.
2. Replace the PSU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
557
C
Zero cross frequency error
When the zero cross signal is 66 or more and it is detected 10 times or more in 11
detections, the machine determines that input 60 Hz and SC557 occurs.
• Noise (High frequency)
Check the power supply source.
3. Appendix: Service Call Conditions
74
3
Summary of Contents for MPC 2800 AT-C2
Page 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Page 2: ......
Page 16: ...Overview Component Layout 1 Product Information 14 1...
Page 152: ...2 Installation 150 2...
Page 156: ...3 Preventive Maintenance 154 3...
Page 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Page 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Page 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Page 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Page 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Page 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Page 327: ...Controller Self Diagnostics 325 5...
Page 354: ...MEMO 352...
Page 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Page 356: ......
Page 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Page 360: ...4...
Page 396: ...2 Appendix Maintenance Tables 40 2...
Page 474: ...4 Appendix Process Control Error Conditions 118 4...
Page 476: ...5 Appendix Troubleshooting Guide 120 5...
Page 484: ...5 Appendix Troubleshooting Guide 128 5...
Page 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Page 500: ...7 Appendix Electrical Component Defects 144 7...
Page 854: ...MEMO 498...
Page 855: ...MEMO 499...
Page 856: ...MEMO 500 EN...