082
Target Temp. After Ready
*ENG
[140 to 165 / 155 / 1 deg/step]
Specifies the target temperature for the maintain mode after the machine has reached the
target temperature in warm-up mode.
083
Recovery Target Temp.
*ENG
[140 to 160 / 150 / 1 deg /step]
Specifies the target temperature for the print mode without printing/copying job after the
machine's recovery.
087 Thick 2: FC: Simplex: Ends
*ENG
[130 to 180 / 160 / 1 deg/step]
088 Thick 2: BW: Simplex: Ends
*ENG
089 Thick 3: FC: Simplex
*ENG
[135 to 180 / 165 / 1 deg/step]
090 Thick 3: FC: Simplex: Ends
*ENG
091 Thick 3: BW: Simplex
*ENG
092 Thick 3: BW: Simplex: Ends
*ENG
110 Middle Thick: FC: Duplex
*ENG
[130 to 175 / 160 / 1 deg/step]
111 Middle Thick: BW: Simplex
*ENG
112 Middle Thick: BW: Duplex
*ENG
113 Middle Thick: FC: Simplex: Ends
*ENG
114 Middle Thick: FC: Duplex: Ends
*ENG
115 Middle Thick: BW: Simplex: Ends
*ENG
116 Middle Thick: BW: Duplex: Ends
*ENG
120 Plain2: FC: Simplex
*ENG
[130 to 175 / 155 / 1 deg/step]
122 Plain2: FC: Duplex
*ENG
124 Plain2: BW: Simplex
*ENG
125 Plain2: BW: Simplex: Ends
*ENG
126 Plain2: BW: Duplex
*ENG
127 Plain2: BW: Duplex: Ends
*ENG
8. Appendix: SP Mode Tables
154
8
Summary of Contents for MPC 2800 AT-C2
Page 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Page 2: ......
Page 16: ...Overview Component Layout 1 Product Information 14 1...
Page 152: ...2 Installation 150 2...
Page 156: ...3 Preventive Maintenance 154 3...
Page 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Page 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Page 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Page 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Page 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Page 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Page 327: ...Controller Self Diagnostics 325 5...
Page 354: ...MEMO 352...
Page 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Page 356: ......
Page 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Page 360: ...4...
Page 396: ...2 Appendix Maintenance Tables 40 2...
Page 474: ...4 Appendix Process Control Error Conditions 118 4...
Page 476: ...5 Appendix Troubleshooting Guide 120 5...
Page 484: ...5 Appendix Troubleshooting Guide 128 5...
Page 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Page 500: ...7 Appendix Electrical Component Defects 144 7...
Page 854: ...MEMO 498...
Page 855: ...MEMO 499...
Page 856: ...MEMO 500 EN...