002
Forced Setting
*ENG [0 to 6 / 0 / 1 /step]
Sets the environment condition manually.
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
003
Absolute Humidity: Threshold 1
*ENG [0 to 100 / 4 / 0.01 g/m
3
/step]
Adjusts the threshold value between LL and ML.
004
Absolute Humidity: Threshold 2
*ENG [0 to 100 / 8 / 0.01 g/m
3
/step]
Adjusts the threshold value between ML and MM.
005
Absolute Humidity: Threshold 3
*ENG [0 to 100 / 16 / 0.01 g/m
3
/step]
Adjusts the threshold value between MM and MH.
006
Absolute Humidity: Threshold 4
*ENG [0 to 100 / 24 / 0.01 g/m
3
/step]
Adjusts the threshold value between MH and HH.
007 Temp Threshold
*ENG [–5 to 30 / 5 / 1 deg/step]
2308
[Paper Size Correction]
Adjusts the threshold value for the paper size correction.
001 Threshold 1
*ENG
[0 to 350 / 297 / 1 mm/step]
Threshold 1 ≤ paper:
Paper is detected as "S1" size.
002 Threshold 2
*ENG
[0 to 350 / 257 / 1 mm/step]
Threshold 2 ≤ paper ≤ Threshold 1:
Paper is detected as "S2" size.
003 Threshold 3
*ENG
[0 to 350 / 210 / 1 mm/step]
Threshold 3 ≤ paper ≤ Threshold 2:
Paper is detected as "S3" size.
System Service Mode
205
8
Summary of Contents for MPC 2800 AT-C2
Page 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Page 2: ......
Page 16: ...Overview Component Layout 1 Product Information 14 1...
Page 152: ...2 Installation 150 2...
Page 156: ...3 Preventive Maintenance 154 3...
Page 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Page 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Page 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Page 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Page 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Page 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Page 327: ...Controller Self Diagnostics 325 5...
Page 354: ...MEMO 352...
Page 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Page 356: ......
Page 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Page 360: ...4...
Page 396: ...2 Appendix Maintenance Tables 40 2...
Page 474: ...4 Appendix Process Control Error Conditions 118 4...
Page 476: ...5 Appendix Troubleshooting Guide 120 5...
Page 484: ...5 Appendix Troubleshooting Guide 128 5...
Page 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Page 500: ...7 Appendix Electrical Component Defects 144 7...
Page 854: ...MEMO 498...
Page 855: ...MEMO 499...
Page 856: ...MEMO 500 EN...