006 Absolute Humidity
*ENG
[0 to 99 / 12 / 1 g/m
3
/step]
007 Temp Threshold M
*ENG
[0 to 99 / 10 / 1 deg/step]
008 RH Threshold M
*ENG
[0 to 99 / 50 / 1 %RH/step]
009 AH Threshold M
*ENG
[0 to 99 / 6 / 1 g/m
3
/step]
010 Temp Threshold S
*ENG
[0 to 20 / 1 / 0.1 deg/step]
011 RH Threshold S
*ENG
[0 to 50 / 5 / 1 %RH/step]
012 AH Threshold S
*ENG
[0 to 20 / 1 / 0.1 g/m
3
/step]
013 Non-use Time
*ENG
[0 to 1440 / 360 / 10 min/step]
2015
[Charge AC Adj: Result]
001 Bk
*ENG
[0 to 9 / 0 / 1 /step]
002 M
*ENG
003 C
*ENG
004 Y
*ENG
2101
[Color Registration Correction] FA
These values are the parameters for the automatic line position adjustment and are adjusted
at the factory. However, you must input a value for SP2101-001 after replacing the laser
optics housing unit. For details, see "Laser Optics Housing Unit" in the "Replacement and
Adjustment" section. The value should be provided with the new laser optics housing unit.
001 Main Dot: Bk
*ENG
[–512 to 511 / 0 / 1 dot/step]
002 Main Dot: M
*ENG
003 Main Dot: C
*ENG
004 Main Dot: Y
*ENG
005 Sub Line: Bk
*ENG
[–16384 to 16383 / 0 / 1 line/step]
006 Sub Line: M
*ENG
007 Sub Line: C
*ENG
008 Sub Line: Y
*ENG
System Service Mode
173
8
Summary of Contents for MPC 2800 AT-C2
Page 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Page 2: ......
Page 16: ...Overview Component Layout 1 Product Information 14 1...
Page 152: ...2 Installation 150 2...
Page 156: ...3 Preventive Maintenance 154 3...
Page 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Page 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Page 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Page 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Page 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Page 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Page 327: ...Controller Self Diagnostics 325 5...
Page 354: ...MEMO 352...
Page 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Page 356: ......
Page 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Page 360: ...4...
Page 396: ...2 Appendix Maintenance Tables 40 2...
Page 474: ...4 Appendix Process Control Error Conditions 118 4...
Page 476: ...5 Appendix Troubleshooting Guide 120 5...
Page 484: ...5 Appendix Troubleshooting Guide 128 5...
Page 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Page 500: ...7 Appendix Electrical Component Defects 144 7...
Page 854: ...MEMO 498...
Page 855: ...MEMO 499...
Page 856: ...MEMO 500 EN...