Regulatory Mode Functions
71
9.14 Regulatory Mode Functions
At zero weight, the push-button tare will prompt for a keyed tare when tare function is set to keyed or both.
Regulatory
Parameter
Weight On
Scale
Tare In
System
Front Panel
Key Tare
Front Panel
Key Zero
NTEP
Zero
No
“000000”
Zero
Yes Clear
tare
Zero
Negative
No No
action
Zero
Yes
Clear tare
Zero
Positive
No Tare
Zero
Yes Tare
Zero
Canada
Zero
No “000000”
Zero
Yes
Clear tare
Clear tare
Negative
No No
action
Zero
Yes
Clear tare
Clear tare
Positive
No Tare
Zero
Yes No
action
Clear
tare
OIML
Zero
No
“000000”
Zero
Yes
Clear tare
Zero & Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Zero & Clear tare
Positive
No
“000000”
Zero
Yes
Tare
Zero & Clear Tare
None
Zero
No
“000000”
Zero
Yes
Clear tare
Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Clear tare
Positive
No
Tare Zero
Yes
Clear tare
Clear tare
Table 9-5. Tare and Zero Key Functions for REGULA Parameter Settings
Note
Summary of Contents for Legend 480-2A
Page 3: ......
Page 7: ...iv 480 Legend Series...
Page 83: ...76 480 Legend Series...
Page 84: ......