480 Legend Series
3.2 Configuration Using the Front Panel (Legal for Trade)
The
480
indicator can be configured using a series of menus accessed through the indicator front panel when the
indicator is in configuration mode.
When the indicator is placed in configuration mode,
CONFIG
is shown on the display. The CONFIG menu is the
first of eight main menus used to configure the indicator. Detailed descriptions of these menus are given in
Section 3.2.1 on page 33. When configuration is complete, return to
CONFIG
and press the (
Zero
) key to exit
configuration mode and save changes. Then replace the configuration switch access screw.
To place the indicator into the configuration mode, a configuration switch is accessed by removing the setup switch
access head screw on the enclosure back, see Figure 2-1 on page 10. The switch is activated by inserting a
non-conductive tool into the access hole after pressing the menu switch.
1. Remove setup switch access screw from back of indicator.
2. Using a non-conductive tool, press the button located in the access hole. This allows access to configuration
menus.
Menu
Required
Password*
Menu Function
CONFIG
Configuration
Config
Graduations (scale capacity), Configure zero tracking, zero range, motion band,
overload, tare function, sample rate and digital filtering parameters.
FORMAT
Format
Config
Set primary and secondary units.
CALIBR
Calibration
Config
Calibrate the indicator. See Section 4.0 on page 46 for calibration procedures.
PROGRM
Program
Config
Set power-up and regulatory modes, consecutive numbering and sleep
parameters.
DIG IN
Digital Input
User
Assign digital input functions. Used only if the Relay option is installed.
ALGOUT
Analog Output
Config
Configure the analog output module. Used only if analog output option is
installed.
PASWRD
Password
Config
Enable and edit configuration and user passwords.
USBMEM
USB Memory
Config
Allows the saving and loading of configuration settings from a USB flash
memory device.
TEST
Test
Config
Used to test A/D, test and set Digital I/O, reset the indicator to default settings
and set over and under weighment characteristics.
MENU
Menu
User
Non Legal for Trade settings, such as Audit Trail, view Tare, set Unit ID, view/
print Accumulator, set Time/Date, and Non Legal for Trade setting for
Communication Port, Setpoints and Print Format parameters. See Section 3.1.
Can be accessed without pressing the Setup Switch, by pressing
the Menu key on the front panel.
* Password required for all menus if a password for that level has been entered. See Section 3.2.8.
Table 3-9.
480
Menu Summary