The EDP Command Set
55
Ethernet Functionality
The Ethernet port works in COMMAND mode meaning that it is possible to send any EDP command to the
indicator and receive a response from the indicator accordingly. It is not possible to print from the port.
Command
Description
Values
ETH.DHCP
Dynamic Host Configuration Protocol
(DHCP)
ON – Dynamic allocation of IP address
OFF – Static allocation of IP address
ETH.IPADDRESS
Source IP address, a 4 field value
The range of each field is 0-255
(0-255).(0-255).(0-255).(0-255)
ETH.NETMASK
SUBNET mask, a 4 field value
The range of each field is 0-255
(0-255).(0-255).(0-255).(0-255)
ETH.DEFAULTGATEWAY
Default gate way, a 4 field value
Range of each field is 0-255
(0-255).(0-255).(0-255).(0-255)
ETH.MAC
Returns the MAC address, read only
6 fields, 8 bit each, in hexadecimal base
ETH.SERVER.PORT
The ethernet server TCP port
1-65535
ETH.SERVER.ECHO
Sets the Server Port Echo
ON, OFF
ETH.SERVER.TRIGGER
Server Port Trigger
DEMAND, COMAND, STRLFT, STRIND
ETH.SERVER.TIMEOUT
Server Inactivity Timeout in seconds
0-65535
ETH.SERVER.TERMIN
Server Line Termination
CR or CR/LF
ETH.SERVER.SFMT
Server Stream Format
STR-1, STR-2, STR-3, STR-4, STR-5
ETH.SERVER.EOLDLY
Server End of Line Delay
0-255
ETH.CLIENT.REMOTESERVERIP
Client Remote Server IP Address
Range of each field is 0-255
(0-255).(0-255).(0-255).(0-255)
ETH.CLIENT.REMOTESERVERPORT Client Remote Server TCP Port number
1-65535
ETH.CLIENT.TRIGGER
Client Port Trigger
DEMAND, COMAND, STRLFT, STRIND
ETH.CLIENT.TIMEOUT
Client Inactivity Timeout in seconds
0-65535
ETH.CLIENT.TERMIN
Client Line Termination
CR or CR/LF
ETH.CLIENT.SFMT
Client Stream Format
STR-1, STR-2, STR-3, STR-4, STR-5
ETH.CLIENT.EOLDLY
Client End of Line Delay
0-255
ETH.CLIENT.ECHO
Sets the Client Echo
ON, OFF
Table 6-12. Ethernet Commands
Command
Description
Default Values
GFMT
Gross demand print format string
GROSS<G><NL2><TD><NL>
NFMT
Net demand print format string
GROSS<G><NL>TARE<SP><T><NL>NET<SP2><N><NL2><TD><NL>
ACCFMT
Accumulator demand print format string ACCUM <A><NL><DA> <TI><NL>
SPFMT
Setpoint print format
<SCV><SP><SPM><NL>
Table 6-13. PFORMT EDP Commands
Command
Description
Values
POWER
Determines if indicator automatically powers on
when plugged in or if power key must be pressed.
Read only in Weighing Mode.
AUTO
MANUAL
BKLGHT
Controls the LCD backlight display.
Read only in Weighing Mode.
ON, OFF, AUTO
BKLGHT.AUTO
Controls the LCD backlight display auto off time.
Read only in Weighing Mode.
10SEC, 30SEC, 1MIN, 5MIN, 10MIN
BAT
Reads the battery level. Read only.
Current battery level in millivolts.
USB.DEVICE
Select the USB Device.
HOST, DRIVE, PRINTER
USB.TRIGGER
Set the USB Port Trigger.
DEMAND, COMAND
Table 6-14. MISC Commands