Configuration Using the Front Panel (Legal for Trade)
39
Parameter
Choices
Description
PWRUPM
GO
DELAY
Power up mode – when set to GO, the indicator goes into operation immediately after a brief
power up display test.
When set to DELAY, the indicator performs a power up display test and then enters a 30 second
warm-up period. If no motion is detected during the warm-up period, the indicator becomes
operational when the warm-up period ends; if motion is detected, the delay timer is reset and the
warm-up period repeated.
REGULA
NTEP
OIML
CANADA
NONE
Regulatory mode – specifies the regulatory agency having jurisdiction over the scale site.
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.
NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.
CONSNU
000000
0 – 999999
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value will increment following each print operation when the print format used contains
the <CN>, or consecutive number formatting token. This value is read only.
The initial value of this parameter is set to the start up value specified on the
CONSTU parameter. Changing CONSTU immediately resets the consecutive
number used for printing.
CONSTU
000000
0 – 999999
Consecutive number start up value. Specifies the initial consecutive number (CONSNU) value
used when the indicator is reset or configured.
Consecutive numbering starts with number entered.
Example: If 100 is entered the first ticketed printed will be 100.
ACCUM
OFF
ON
Turns the accumulator on and off. Stores the accumulated weight, time and date of last
accumulation.
RTZGRD
0
0 – 999999
Return to zero grads to re-arm the accumulator. Default = 0.
Defines the number of graduations from Zero that the weight has to go below before the
accumulator will be re-armed.
DATE
DATFMT
DATSEP
Allows selection of date format and date separator. See
Date sub-menu
for parameter
descriptions.
TIME
TIMFMT
TIMSEP
Allows selection of time format and separator. See
Time sub-menu
for parameter descriptions.
SLEEP
NEVER
1MIN
2MIN
5MIN
10MIN
Sleep mode. When weight is stable, no buttons have been pressed, and the weight is below the
sleep weight threshold (WGTHRH), the indicator will enter the sleep mode in the time defined in
the SLEEP Parameter. A NEVER setting will disable the sleep mode.
See Section 9.6 on page 65.
The SLEEP mode will only operate if the indicator is operating on Internal Battery
Power - disconnected from AC power.
Setting the WGTHRH or DDTHRH parameters to 0 also disables sleep mode.
Tare is removed if the indicator goes into sleep mode.
STDBY
1SEC
5SEC
10SEC
15SEC
30SEC
60SEC
OFF
Controls the Standby mode.
When in the sleep mode, at the number of STDBY seconds set, the indicator will wake if:
• there is weight on the scale of more than the WGTHRH value
• the weight has is changed greater than DDTHRH value
• it detects that a button is being pressed
Table 3-14. Program Menu Parameters