26
480 Legend Series
Parameter
Choices
Description
COM-1
TRIGER
BAUD
BITS
SBITS
TERMIN
EOLDLY
ECHO
PRNMSG
Specifies settings for COM-1.
COM-2
TRIGER
BAUD
BITS
SBITS
TERMIN
EOLDLY
ECHO
PRNMSG
STRUR
Specifies settings for COM-2.
STREAM
Specifies the operating mode of the indicator. See Section 9.4 on page 65.
NONE
Indicator operates normally, COM-2 will not stream, even if the TRIGER is set to a streaming
parameter (STR1-5)
LOCAL
Indicator operates normally, data streaming occurs on COM-2 if the TRIGER is set to stream
data (STR1-5)
REMOTE
Indicator acts as a Serial Data scale, displaying values based on a received steam of Serial
Data into COM-2. It also sends keypress commands back through COM-2 to the Local
indicator.
Submenus COM-1 and COM-2
TRIGER
(COM-1)
Specifies the ports mechanism for triggering a transmission of data.
DEMAND
Demand port
–
printing is performed by pressing the Print key or when a KPRINT EDP
command is received. This port will also allow operation and EDP commands.
PRN
Printer Port – printing is performed by pressing the Print key. The port does not allow
operation of EDP commands.
NONE
Port is inactive.
COMAND
Command port
–
allows operation of EDP commands, but will not print.
TRIGER
(COM-2)
NONE
Port is inactive.
PRN
Printer Port – Printing is performed by pressing the Print key. The port does not allow
operation of EDP commands.
STR1
Port is used to transmit a continuous stream of data according to RLWS stream format.**
STR2
Port is used to transmit a continuous stream of data according to Toledo8142 stream
format.*
STR3
Port is used to transmit a continuous stream of data according to Cardinal738 stream
format.*
STR4
Port is used to transmit a continuous stream of data according to Weightronix WI-120
stream format.*
STR5
Port is used to transmit a continuous stream of data according to consolidated stream
format.*
*STREAM must be set to local to enable streaming.
See Section 9.3 on page 62 for more information on Stream formats.
Com-2 streams simultaneously on both the RS-232 and 20mA outputs.
BAUD
9600
19200
38400
1200
2400
4800
Baud rate. Selects the transmission speed of data.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data.
Table 3-3. Serial Menu Parameters
Note