Ethernet Option
67
Save the Configuration
1. Attach a flash drive to the USB port.
2. Enter the configuration menu and navigate go to
USBMEM
3. Press , then press or to select
SAVE
. See Section 3.2.9 on page 43.
4. Press the
Tare
key. A copy of the configuration DUMPALL, will be written to the drive in an ASCII text
file with the name “480_<UID>.txt”, where <UID> is replaced with the unit ID configured in the indicator.
Load a Configuration File
1. Install the file on the flash drive. The file can be either of two formats, a configuration dumpall text file, or
a configuration file created by the Revolution indicator configuration utility. The file name must be
“480_<UID>.txt” for a text file, or “480_<UID>.rev” for a Revolution file, where <UID> is the currently
configured Unit ID of the indicator.
2. Attach the flash drive to the USB port.
3. Enter the configuration menu and navigate go to
USBMEM
4. Press , then press or to select LOAD. See Section 3.2.9 on page 43
5. Press the
Tare
key. If a file is found on the flash drive with a <UID> that matches that currently in the
indicator, it will be loaded. If the loading of the file fails for any reason, an error will be displayed.
Edit and Save File on Flash Drive with Revolution
1. To open the file, select the appropriate 480 module and open it.
2. Use the Import function in the File menu to import the configuration parameters into Revolution.
9.8.3
USB Printing
When set to
PRINTR
mode, the USB port can be connected to a USB printer using an appropriate USB cable.
To configure (see Section 3.1.4 on page 29):
1. Set the USB port to
PRINTR
.
2. Set the trigger to
DEMAND
.
3. Press the
key or call a remote print command to print to the USB printer.
9.9
Ethernet Option
In firmware version 1.03 and later, an optional Ethernet/USB board is supported.
With the Ethernet option installed, the
480
can either be connected directly to a PC via the Ethernet connection, or
to an Ethernet network.
The
480
Ethernet option will support two simultaneous connections, one as a server, the other a client. It can be set
up with a static, or DHCP-provided IP address. Both ports can be used to communicate to the indicator using all the
available serial EDP commands. Both ports can be set to print on demand and can stream data.
The server port has a configurable TCP port number, and can accept a single remote client connection.
The client port can be configured to connect to a remote server’s IP and TCP port number upon power up, or
whenever there is data to send.
Connection is made via a RJ45 connector inside the indicator on the Ethernet/USB option board.
For details on all the configurable parameters for the optional Ethernet ports, see Section 3.1.3 on page 28.