62
480 Legend Series
Example:
If the annunciator status value returned on the ZZ command is 145, the gross, standstill and lb annunciators are lit.
The number 145 represents the sum of the values for the standstill annunciator (128), gross mode annunciator (16)
and the lb/primary units annunciator (1)
.
9.3
Continuous Data (Stream) Output Formats
When the trigger setting for COM-2 is set to one of the stream formats (STR1-STR5), or the Ethernet client or
server trigger setting is STRLFT or STRIND, data is continuously streamed from the appropriate port in one of the
five fixed formats that follow.
Figure 9-1. STR-1 Rice Lake Stream Data Format
Set format 5 if receiving device cannot read a status bit Z.
Decimal
Value
Annunciator
1
lb/primary units
2
kg/secondary units
4
Tare entered
8
Keyed tare entered
16
Gross
32
Net
64
Center of zero
128
Standstill
Table 9-3. Status Codes Returned on the ZZ Command
<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <TERM>
ASCII 02
decimal
Polarity:
<space> = Positive
<–> = Negative
Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.
L = pounds
K = kilograms
T = tons
G = grams
O = ounces
G = Gross
N = Net
Status:
<space> = valid
I = Invalid
M = Motion
O = Over/under range
Z = COZ
<CR> <LF>
or <CR>
Note