Configuration Menu Structures and Parameter Descriptions
Figure 3-9. Configuration Menu
Parameter
Choices
Description
GRADS
10000
1 – 100000
Graduations – specifies the number of full scale graduations. The value entered must be in
the range 1-100 000 and should be consistent with legal requirements and environmental
limits on system resolution.
ZTRKBN
0 dd
0.0 – 3.0dd
Zero track band – automatically zeros the scale when within the range specified, as long as
the input is within the configured zero range (ZRANGE parameter). Selections are ± display
divisions. Maximum legal value varies depending on local regulations.
ZRANGE
2%
1% – 100%
Zero range – selects the range within which the scale can be zeroed. The 2% selection is ±
2% around the calibrated zero point, for a total range of 4%. Indicator must be at standstill
to zero the scale.
INIZR
0 %
0 – 100%
Initial Zero Range at power up – see Error messages HINOFF and LINOFF in Section 9.1.1
If on power up the weight value is between the ±% range specified of Calibrated Zero, the
indicator will zero off that weight. If outside that range, the indicator will display HINOFF or
LINOFF, depending on whether the initial reading is above or below the range.
If not set at zero, hopper/scale MUST be empty when powered up.
MOTBAN
0.1d
0.0d – 100d
Motion band – sets the level, in display divisions, at which scale motion is detected. If
motion is not detected, the standstill symbol lights.
Some operations, including print, tare and zero, require the scale to be at standstill.
Maximum legal value varies depending on local regulations.
Setting the MOTBAN setting to 0.0 disables motion sensing, the scale will
always be considered stable.
Table 3-10. Configuration Menu Parameters
GRADS
ZTRKBN
ZRANGE
INIZR
MOTBAN
OVRLOA
DSPRAT
SMPRAT
CONFIG
FORMAT
CALIBR
PROGRM
DIG IN
ALGOUT
PASWRD
USBMEM
MENU
TEST
ROLFIL
5 HZ
10 HZ
20 HZ
40 HZ
010000
0 dd
2 %
0 %
0.1 d
FS-2%
FS-1D
FS-9D
FS
0.10 SEC
0.25 SEC
0.50 SEC
0.75 SEC
1.00 SEC
NONE
DIGFIL
ADPFIL
OFF
ROLFIL
BOTH
NOTARE
PBTARE
KEYED
TAREFN
ADPFIL
See
See
Note
Note