User Menu Setup
29
3.1.4
USB Menu
Figure 3-5. USB Menu Layout
Table 3-5. USB Menu
SERVER/CLIENT Submenu
TRIGER
Selects the operation of the port.
DEMAND
Allows operation of EDP commands and will print.
COMAND
Allows operation of EDP commands only, does not print.
STRLFT
Stream legal for trade scale data – data is transmitted at the configured display update
rate. Will also accept EDP commands and print.
STRIND
Stream industrial scale data – data is transmitted up to the configured A/D sample rate.
Will also accept EDP commands and print.
TIMOUT
0
0-65535
Timeout – inactivity disconnect timeout. A connection (either client or server) is closed if
there is no activity before the timeout expires. Time is in seconds. A timeout value of 0
disables the inactivity disconnect.
TERMIN
CR/LF
CR
Termination. Selects the termination character(s) for data sent from the port.
SFMT
STR1-5
Stream format – specifies the stream format used for streaming output of scale data
(TRIGER=STRLFT or STRIND). See Section 9.3 on page 62.
PORT
10001
1-65535
The TCP port number of the 480 server.
Server level only
.
RMOTIP
0.0.0.0
Remote Host IP address – IP address of the Remote Host (Server) the 480 Client will
connect to.
Client level only.
RMPORT
1
1-65535
Remote Host TCP Port number – The TCP Port of the Remote Host (Server) the 480 Client
will connect to
Client level only.
EOLDLY
0
0-255
Port end-of-line delay – specifies (in 0.1 second intervals) the delay between transmitted
lines of data.
ECHO
OFF
ON
Specifies whether characters received by the port are echoed back to the sending unit.
Parameter
Choices
Description
DEVICE
HOSTPC
The port is assigned to a HOSTPC, the protocol is a demand type similar to serial
communications demand mode, meaning that the port supports EDP commands and Printing.
DRIVE
The port is assigned to a flash drive, the data is written in a FAT32 system, no special driver is
required.
Use the USBMEM Load and Save functions, found in the Configuration Menu (Section 3.2.1 on
page 33), to load configuration data to or from a flash drive.
PRINTR
When set to PRINTR mode, the USB port can be connected to a USB printer using an
appropriate USB cable. See Section 9.8 on page 66.
TRIGER
COMAND
Allows operation of EDP commands only. Does not print.
DEMAND
Allows operation of EDP commands and prints.
Parameter
Choices
Description
Table 3-4. Ethernet Menu Parameters (Continued)
ETHNET
USB
PFRMAT
...
...
TRIGER
DEVICE
PRINTR
HOSTPC
DRIVE